Categories




Megger DRLO 100, DRLO 200, DRLO 600

These are digital microhmmeters. They are small and do not weigh more than 15 kg. They test currents ranging from 10A to 500 A DC. They have a memory on board which can be used for 300 test results as well as for notes and it has a RS232 port that can be used to download stored results or it could be used to send the output real time to the printer. There is an alphanumeric keypad which allows the user to set the current directly by typing the value. The instruments come with 5m test leads as well as software which can be used for downloading.

These instruments measure resistance between 01. Micro ohms and 1 ohm at high currents. They are versatile and they provide test currents ranging from 10 to 600 amps based on the load resistance as well as the supply voltage. The display is the liquid crystal kind and it provides all the information needed so that a test can be performed. All the parameters as well as the measurements of the results of the test are displayed.

This has a unique design and the size as well as the weight of the instrument is kept at a minimum. The size makes it multipurpose and it can be used at home, in the workshop, in the field or the production floor. This is perfect for testing circuit breaker contacts, for busbar joints, switch contacts or other applications where high currents are required.

The DLRO600 checks the continuity of the test circuits, they ramp the test current to the desired level. The keyboard also is used to set the lower as well as the upper limits for the result and it prevents excessive currents being used by the upper limit being set in the allowable range.

There are 4 terminal measurement techniques which are used to cancel the resistance of the test leads from measurement. There are 3 modes of operation which can be selected from the on screen menu.

There is the continuous mode which the users can set for monitoring resistance over a long period of time. In this the leads are to be connected and the test current needs to be selected and the test button is to e pressed. The current is continuously passed and the voltage is measured at 2 second intervals till the button is pressed to stop the test.

The Normal mode consists of connecting the leads and selecting the current and pressing Test. The current gets ramped to the desired levels, is held for 2 seconds and ramped down. This takes a total of 7 seconds.

Auto mode consists of the user selecting the current, connecting the leads and pressing the Test button. The lamp with flash to show that it is ready to be tested. When the leads are connected the test starts. In order for a repetition, the contact needs to be broken and contact remade.

The maximum continuous test time is more than 60 seconds at 600 A.

Megger DRLO 10

Megger DRLO 10 are low resistance ohmmeters and they are able to measure resistances of the 0.1 micro ohms to 2 kilo ohms. These instruments provide a test current of a maximum 10 Amps and this gets automatically selected based on the resistance which is being tested. However, the person can override the automatic selection and thus they are able to select their own test current.

The LCD display and indicators display not only the value but the units as well. The display has a clear backlight as well.

The measurement of resistance takes around 2.5 seconds and it consists of measuring the forward current as well as the reverse current and the average is displayed. The DLRO 10X shows not only all three values but also it can be limited to measuring just the forward current.

There is a rechargeable nickel metal hydride battery and this allows one thousand 10 amp tests to be completed on the same charge. The battery module has intelligent circuitry and that prevents damage done to the battery due to overcharging. There is also an indicator for the state of the battery. There is a removable lid which has a hinge at the back and this is held by magnetic catches at the top panel. The lid can be removed if it is required as well.

There are accidental connection protections for the instrument up to 600 V DC applied between any of the pairs of 4 terminals for max 10 secs. However, when there are such high voltages which are applied there could be internal heating and there could be errors upto 30 digits immediately. However, in 2-3 minutes the accuracy will be restored completed.

The test current is indicated through lamps which are on the left of the panel and the value measured is displayed in the main widow and on the right the units will be mentioned.

When there is an excess of 100 mV 50/50 Hz the noise lamp will get lit and this then is a signal that the accuracy may be compromised and so cannot be relied upon.

If there is external voltage which is applied to the terminals then the V lamp flashes. This warns the user that the item is live under test and it could be dangerous. In this condition the test is not to be performed. The V lamp is lit when there is more than 50 V which is applied between the current and the voltage terminal.  If the voltage is between just the voltage terminals or just between the current terminals then the 100 V peak lamp or 5V peak lamp is lit respectively. If all terminals are at a high voltage, the lamp will not operate.

If the I lamp is lit, it indicates that current more than 1 mA is flowing even after completion of the test. This means that there is discharging as the inductive load was tested. In such cases the current loop is not to be disconnected till the I lamp goes out.

Megger 247001

Megger 247001 is an equipment which is used to check resolutions to 0.1 micro ohms on a range of 599.9 micro ohms. The equipment is accurate as it has an accuracy of + or – 0.25% and this is fitted with a digital readout. It is practical and simple as well as a very reliable means of testing low resistance. These machines are used for quality control in production. They also operate on the 4 wire measurement principle. The lead and contact resistances are eliminated using this.

These digital low resistance ohmmeters meet the ANSI standards of safety requirements and there is no shock hazards that one can get from the instrument and so this can be used in wet and in outdoor environments.

Before using the instrument for the first time, the batteries should be charged. Also one should remember with regards the zero offset in 0-1 counts which are over 15-35 degrees Celsius, you will be able to get full accuracy using the forward and reverse switch in order to average the readings. There is also an internal zero adjustment which is provided.  In conditions of very low resistance, the reverse reading is possible by holding the forward reverse switch in the position which is the reverse one. The minus sign will be in the display when the reverse position is there. This however should be disregarded when the average is being calculated.

The on off switches are toggle switches which are used to energize the circuits and after the on off switch has been closed, post 2 seconds you will get the final reading.

The red LED display has 4 digits which are 0.5” high and it also has a decimal point as well as negative sign. If there is an over range input then the upper right segments of the digits flash.

The requirements of the test lead resistances are that there are no limitations to the potential leads and the current leads each has a nominal of 20 milliohms. The deviations affect the current however, the deviations do not affect the accuracy. The only exception is if it is very large in comparison with the measuring range.

The equipment consists of a battery condition meter and this meter is used to check the state of the batteries. The battery test however is only valid when the instrument operates on the range where it was meant to be tested on. If the meter shows a red zone, the batteries need to be charged overnight or for 14 hours. There is a separate charger unit which can be plugged into the receptacle on the measuring unit. The full charge takes 14 hours but charging can continue even when the instrument is in operation.

The charger and the measuring unit have a molded rugged case which has handles as well as removable hinged lids. This can also double up as a sun shield and the charger case too is similarly constructed and there is space in it where the test leads can be stored.

Megger 247001

Megger 247001 is an equipment which is used to check resolutions to 0.1 micro ohms on a range of 599.9 micro ohms. The equipment is accurate as it has an accuracy of + or – 0.25% and this is fitted with a digital readout. It is practical and simple as well as a very reliable means of testing low resistance. These machines are used for quality control in production., They also operate on the 4 wire measurement principle. The lead and contact resistances are eliminated using this.

These digital low resistance ohmmeters meet the ANSI standards of safety requirements and there is no shock hazards that one can get from the instrument and so this can be used in wet and in outdoor environments.

Before using the instrument for the first time, the batteries should be charged. Also one should remember with regards the zero offset in 0-1 counts which are over 15-35 degrees Celsius, you will be able to get full accuracy using the forward and reverse switch in order to average the readings. There is also an internal zero adjustment which is provided.  In conditions of very low resistance, the reverse reading is possible by holding the forward reverse switch in the position which is the reverse one. The minus sign will be in the display when the reverse position is there. This however should be disregarded when the average is being calculated.

The on off switches are toggle switches which are used to energize the circuits and after the on off switch has been closed, post 2 seconds you will get the final reading.

The red LED display has 4 digits which are 0.5” high and it also has a decimal point as well as negative sign. If there is an over range input then the upper right segments of the digits flash.

The requirements of the test lead resistances are that there are no limitations to the potential leads and the current leads each has a nominal of 20 milliohms. The deviations affect the current however, the deviations do not affect the accuracy. The only exception is if it is very large in comparison with the measuring range.

The equipment consists of a battery condition meter and this meter is used to check the state of the batteries. The battery test however is only valid when the instrument operates on the range where it was meant to be tested on. If the meter shows a red zone, the batteries need to be charged overnight or for 14 hours. There is a separate charger unit which can be plugged into the receptacle on the measuring unit. The full charge takes 14 hours but charging can continue even when the instrument is in operation.

The charger and the measuring unit have a molded rugged case which has handles as well as removable hinged lids. This can also double up as a sun shield and the charger case too is similarly constructed and there is space in it where the test leads can be stored.

 

DV Power RMO 100G product review

The various micro ohmmeters which are powered by the RMO series instruments for measurement of non-inductive test objects. All of the RMO 100G instruments are based upon the one of the advanced switch mode technique that is available today in the market. They use automatically regulated kind of test ramps to generate a ripple free DC current. The test RMO 100G ramps measures the decreasing and increasing current and this type of approach helps in magnetic transients.

RMO is in the industry for last 15 years and have over 18 products of the highest precision micro ohmmeters. These are one of its own kind, so that people can have the appliance for the long term with them. The range of the appliance is from 0.1 µΩ – 999.9 mΩ.

 

Features of DV Power RMO 100G:

1.   The DV power is equipped with all the advanced features of the equipment with Single and CONTIN test and with DTRtest as well.

2.   The device is available with both side grounded units to be used by the user in any other way with the options it is very much possible to make the various safer measurements for the breakers with all of the terminals of the breaker grounded.

3.   The device comes with a warranty of 3 years for the user for the parts and labor.

4.   The Remote control unit or RMO is considered as an optional control unit which is used to start and stop the various tests in the remote location.

5.   The device is used for welding joints and cable splices.

6.   The power consumption of the device is approximately 1160 VA

7.   Environmental conditions that the device requires to be operational is about 2000m and the temperature below -10 degrees.

8.   Extension cables and current cables are available with the device for the product to go through various changes.

 

The Benefits of DV Power RMO 100G:

1.   The device is available for middle, high and low switch circuit breakers for the users.

2.   The device is used for various high current bus jar points to be taken care off.

3.   The device comes with DV-Win PC software on which the application of the device works for the smooth functioning.

4.   The device comes with electromagnetic compatibility for the users.

The device has been one of the boon to the market as they have existed from more than a decade, and have proved to be one of the best in all the kind of categories of the future. The device has applications in one of the high, low and middle voltage disconnecting switches. The device can generate a DC current using the CONTIN menu. A full output is available with 230V power supply and do cater to the same as well. The best part with the company so far is that they strictly adhere to their guidelines and do not shake from them in any case. So, if you are looking for something more sustainable then do go for the same as they have the one of the most exclusive offer for you. 

The AEMC model incorporates the optimized protection and filters for various measurements in the subsequent electrical substations. The model can also be used to measure accurately on high voltage circuit breakers, switches, bus bars and measure low contact resistances for the various test current which is up to 200A. The device employs approximately the 4-terminal methods and their contact resistances as this is controlled by Kevin to eliminate the errors.

 

The resistance digits can be shown on the screen of the model and that can depict to almost 4.5 digits to mark the accuracy of the value taken. The test current values can be adjusted by the operators and can be displayed on the screen.

 

Features of AEMC 6292:

 

1.    The device performs the required tests on both the sides of the switchgear grounded in.

2.    The devices come with the four languages so that a lot of people can cater to the device and can use them for the services required.

3.    There are lots of programmable test duration of 120 seconds at least. The two modes for manual and programmable test selection that is available for the AEMC 6292.

4.    The user can access the test results directly on the screen of the AEMC 6292.

5.    The LCD is very large and stores up to 8000 test results.

6.    USB direct communication is there with the PC and the same also comes with the inbuilt printer to have the access to various files in the output form.

7.    The device is light weighted, rugged and comes with a water resistant case for the users.

8.    The AEMC 6292 measure the resistance if 1 ohms.

9.    The device is installed with the cooling systems to improve the number of tests that needs to be performed in a day.

 

The Benefits of AEMC 6292:

 

1.    The device is used in various applications by the users and especially used in the industries like for testing pipeline, rail frame, switchgear resistance etc. bonding.

2.    The model has the multiple functions to be displayed on the screen and that makes it one of the favorites of many people.

3.    The device is equipped with the feature of measuring the resistances of 1Ω.

4.    The features keep on updating according to the market and the users are updated with the newly released videos so that they can use the device accordingly.

5.    The direct printouts can be used to take the files through data view from the software as well as PC.

AEMC Ohmmeter is one of the premium product in the market for the calculation of the resistance ranging from 2500 ohms to 0.1 ohms. This specific range makes the product as one of its kind in the market that no one has catered till now to the wall of the same. The product takes care of the safety of the user in the first hand and describes the attachment of the fuse in the body of the device to protect the user from various hazards that they can go through if they are not installed at the place. There are almost seven current ranges are there with test currents ranging from 1 ohms to 10 ohms. There are internal circuitry system is installed as well in the device to protect the same at the time of when the current is shut off. These are some of the unique features that the company is catering to from a long time and due to these features, the product is considered to be one of the unique ones which have the power to provide a kind of customer satisfaction which they have never been to.

Features of AEMC 6250:

The AEMC 6250 is one of the ohmmeters which can be used to measure the lowest resistance in the testing laboratories. Let’s see how many, more the features the device have for the users:

1.    The device has a huge display of 2.25 * 4.00 that is used to display the resistance, reference, metal type, ambient temperature and test currents.

2.    There are two fuses that are installed behind the front panel that can be used to protect the storage energy against the various loads.

3.    There is an inbuilt 10A switch is installed in the device to protect against the overheating when the device is used continuously.

4.    The device offers manual or automatic compensation to the users.

5.    The device can store up to 1500 results.

6.     The users can select various metal types ranging from Aluminum, copper for the temperature compensation.

7.    There are two programmable alarms are there to generate and track the high or low triggering of switches.

8.    The user can select between various resistive or automatic test modes.

 

The Benefits of AEMC 6250:

1.    The device have various applications in various industries ranging from component measurement, mechanical bond tests, terminal to wire connections etc. these applications across the industry make the device as one of the unique and that’s why is used by many consumers loved to use the same.

2.    The device comes with rugged or sealed case to protect from the adverse environmental conditions.

3.    The device comes with a large backlit LCD display and have the kind of exposure and screen which no other device have till now.

4.    The device supports various instantaneous, multiple or continuous test modes.

The key feature of these is the high performance and this is based on the technique commonly known as the four point measuring kind. These instruments are optimized to measure highly inductive circuits and low resistance measurements. The design of these instruments are based on the needs of the transformer manufacturers as well as the utilities industry. The requirements are of a portable unit which has ease of operation and yet has high levels of accuracy.

This has an inbuilt DC supply of 2.5 kW and the most demanding resistance can be measured. The DC current too is adjustable right up to 50A so that various resistance values starting from 0.1µΩ right up till 20 kΩ can be measured. This 50V DC voltages are good even for the largest transformer to get saturated in seconds.

The instrument is used to measure the resistance even of windings until 3 serially connected ones simultaneously. The temperature of the test object can also be measured as well as the readings for the resistance are compensated for the temperature due to the aluminum and copper windings.

Post the completion of the test, the discharge circuit ensures that the stored magnetic energy is dissipated. The discharge too is continuously monitored and there are indicators to inform when the test leads can be removed safely.

This is a completely automated instrument and there is no range adjustment which is needed. The field test reports can also be printed if need be and it can also be sent through the RS-232C interface. From there it can be connected to a notebook or PC. In cases of factory usage, control can be done remotely using a host computer.

Features

This instrument has valuable features like the resistance measurement is completely automated and it can be used for any type and size of windings.

The graphics display is large and it shows in a glance all the data. It also helps with easy and quick operation of instruments

It is rugged in design and compact as well. It can be used in factory applications and in harsh environments as well as in the field.

There are three measurement channels which are independent of each other and they allow for testing of windings which are in three series connected simultaneously.

It allows for data exchange to a computer or printer without the need of any other software

It can be operated remotely.

The Benefits

This instrument allows for unmatched speed, accuracy and range. These are cost effective as well as reliable

This has a circuit which enables the discharge safely along with proofs so there is no harm or damage to equipment, instruments or people.

This allows for saturation of even the largest of power transformers in a very short span of time.

It can be operated either in combination with a transformer turns ratio meter or as a single instrument.

This is therefore has a host of applications.

The RMO20TW Winding Ohmmeter is optimum for my use. This is a standalone machine and this instrument is PC controlled and is digital. It is designed for proper detailed analysis done on tap changers of on-load and they are used to measure resistances of test objects which are used all over in the power industry and other related industries.

The most common uses of RMO 20TW winding ohmmeters are for testing and commissioning as well as manufacturing of transformers, tap changers of the on-load kinds, the tap changers that are de-energized, the electrical motors as well as generators, cable splices as well as high current busbar joints.

It also helps to create the measurement of temperature and resistance in the heat run tests. This is usually done with DV-Win software.

It is used for measuring of the two channel winding resistance so that on a single phase simultaneous winding resistance can be measured up to two windings. It also detects interruptions during the on load tap changers which are one on a single phase and it is used for the heat run test so that the hot spot temperature can be obtained along with the graph for resistance during the cooling process.

There are safety features which are part and parcel of these devices. As safety features the red LED remains lit till the energy is reduced to a harmless level. It also has protection against parasitic voltages or currents. The RMO-TW ground connector is to be connected to protective ground. However, only the cable that is provided should be used and this connection should first be done before any other connections and it should also be the last to be removed after all the connections for the same purpose.

When there are any operational errors, it is seen by the red LED as well as it is accompanied by the alarm and to further strengthen the gravity of the situation, the display too shows an error status. When the alarm buzzer is to be stopped, the message has to be removed from the display. This is done by pressing STOP.

The accuracy is another feature which is most notable. Infact the RMO-TW instruments have accuracy of + or – 0.2% rdg 0.2% F.S.

The dimensions of the equipment is 19.8 cm x 25.5 cm x 38 cm. The RMO TW series are lightweight and the RMO 20TW weighs 7.5 kgs while the RMO 30TW weighs 8.5 kgs. There are two channels to measure the resistance and there is a verification for on-load tap changers. It has automatic resistance measurement for the test for heat runs and its circuit is meant for automatic discharge. The standards applicable are category II for overvoltage or installation, degree 2 for pollution and UL 61010-1 CAN for safety.

The instruments are shipped with the following accessories: DV-Win PC Software and USB cable, mains power supply cable and a ground cable.

The software allows for observing and controlling of the test as well as analyzing and saving the results on the PC. The test report can then be arranged in different formats.

The Megger MTO 300 comes in 2 versions. This is controlled by software which runs on my external PC or it can also run on a transformer test product which has a computer on board. This is totally self contained and it has the most powerful integration. The base model is so designed that it can be controlled remotely from the PowerDB software on the external PC or through the test product with the on board computer.

What I personally like is the 8.4 inch display which is colored and it has a full QWERTY keyboard. The VGA has a full color Transreflective screen and can be seen even in bright sunlight. It has an automated 8 terminal as well as 6 winding measurement capability. Thus it saves the users time, who can test all the 6 normal windings rather than having to disconnect and reconnect the leads for testing. It offers for simultaneous winding magnetization. These are used to test the operation of the tap changers and its auto demagnetization as well as automatic discharge is valued highly since it adds to the safety aspect.

The MTO 300 series also have the lead set of the Megger TTR300 series. The users who test both the winding resistance and turns ration can save money and time as only one set is required which has to be connected to the transformer.

The testing offered has 6 winding measurements and also 3 winding measurements of LV and HV windings as well as a single test for winding. The range of testing current is 10A and it has a maximum 50V which can be tested.

The safety feature is such that the discharge is safely done post completion of the test and when a lead is disconnected accidentally, or sometimes if the power is lost while the test is on.

The transformer also has a demagnetization feature so that the core is demagnetized when the test is completed. That way there is no high current inrush when again the transformer is used. This also works for testing the resistance.

This has a time saving feature where it can be used for winding magnetization simultaneously of HV as well as LV windings during testing.

This software is great when used with the MTO 300 series and this is easy to read. This helps to set up the speed instrument and test operations. It also has results which are comparable against the pass or fail limits of the users and it can be stored in XML data format. This allows historical data to be saved and ten results can readily be compared and trended using this.

It allows for simultaneous winding magnetization so that accurate and fast dc winding resistance can be measured of loads that have high induction.

The Vanguard Instruments WRM line is also a very popular instrument. They come in a range of current outputs ranging from 10, 20 and 40 Amp. They are easy to use and reliable units. They are also better priced than the Raytech units which are almost a comparable unit. The one down fall of the Vanguard unit is the size and line testing only ( No Battery). If you don’t mind a bigger case and like to save some money we definitely recommend the Vanguard WRM line for winding resistance testing. 